נגישות
menu      
חיפוש מתקדם
תחביר
חפש...
הספר "אוצר וולקני"
אודות
תנאי שימוש
ניהול
קהילה:
אסיף מאגר המחקר החקלאי
פותח על ידי קלירמאש פתרונות בע"מ -
Studies on aeration with refrigerated air-I. Chilling of wheat in a concrete elevator
Year:
1973
Authors :
דונהאי, עזרא יונתן
;
.
נברו, שלמה
;
.
קלדרון, משה
;
.
Volume :
9
Co-Authors:
Navarro, S., Ministry of Agriculture, Institute for the Technology and Storage of Agricultural Produce, Stored Products Division, Jaffa, Israel
Donahaye, E., Ministry of Agriculture, Institute for the Technology and Storage of Agricultural Produce, Stored Products Division, Jaffa, Israel
Calderon, M., Ministry of Agriculture, Institute for the Technology and Storage of Agricultural Produce, Stored Products Division, Jaffa, Israel
Facilitators :
From page:
253
To page:
259
(
Total pages:
7
)
Abstract:
Two-hundred and forty-five tonnes of wheat in a concrete vertical bin were cooled by aeration with chilled air from a chilling unit (with a cooling capacity rated at 42,500 kcal/hr) to prevent development of insect populations. Initial temperatures of 21-21·5°C were lowered after 94 hr of cooling to 9·9-12·7°C. Under the ambient conditions the rate of cooling was limited by the aeration system of the bin. Cooled air entering the bin was at relative humidities higher than those in equilibrium with the grain moisture content and this caused moistening of grain around the aeration duct to above the critical level for safe storage under local conditions. A re-heater incorporated in the unit designed to reduce relative humidity of the cooler air was inefficient for the cooling of dry grain and reduced the cooling efficiency of the unit. © 1973.
Note:
Related Files :
עוד תגיות
תוכן קשור
More details
DOI :
10.1016/0022-474X(73)90008-8
Article number:
0
Affiliations:
Database:
סקופוס
Publication Type:
מאמר
;
.
Language:
אנגלית
Editors' remarks:
ID:
20391
Last updated date:
02/03/2022 17:27
Creation date:
16/04/2018 23:36
Scientific Publication
Studies on aeration with refrigerated air-I. Chilling of wheat in a concrete elevator
9
Navarro, S., Ministry of Agriculture, Institute for the Technology and Storage of Agricultural Produce, Stored Products Division, Jaffa, Israel
Donahaye, E., Ministry of Agriculture, Institute for the Technology and Storage of Agricultural Produce, Stored Products Division, Jaffa, Israel
Calderon, M., Ministry of Agriculture, Institute for the Technology and Storage of Agricultural Produce, Stored Products Division, Jaffa, Israel
Studies on aeration with refrigerated air-I. Chilling of wheat in a concrete elevator
Two-hundred and forty-five tonnes of wheat in a concrete vertical bin were cooled by aeration with chilled air from a chilling unit (with a cooling capacity rated at 42,500 kcal/hr) to prevent development of insect populations. Initial temperatures of 21-21·5°C were lowered after 94 hr of cooling to 9·9-12·7°C. Under the ambient conditions the rate of cooling was limited by the aeration system of the bin. Cooled air entering the bin was at relative humidities higher than those in equilibrium with the grain moisture content and this caused moistening of grain around the aeration duct to above the critical level for safe storage under local conditions. A re-heater incorporated in the unit designed to reduce relative humidity of the cooler air was inefficient for the cooling of dry grain and reduced the cooling efficiency of the unit. © 1973.