Chamber response time: A neglected issue in gas exchange measurements
Year:
2009
Source of publication :
Photosynthetica
Authors :
רווה, ערן
;
.
Volume :
47
Co-Authors:
Weiss, I., Department of Life Sciences, Ben-Gurion University of the Negev, Beer Sheva 84105, Israel
Mizrahi, Y., Department of Life Sciences, Ben-Gurion University of the Negev, Beer Sheva 84105, Israel
Raveh, E., Gilat Research Center, Agricultural Research Organization, Ministry of Agriculture, mobile Post Negev, 85280, Negev, Israel
Facilitators :
From page:
121
To page:
124
(
Total pages:
4
)
Abstract:
When the dimensions of standard commercial chambers for measuring gas exchange cannot accommodate the object being measured, scientists construct their own chambers. The time needed to reach chamber steady state (chamber response time) depends on net system volume (e.g. chamber and tubing volume) and airflow. Unfortunately, some authors take chamber response time into consideration while others ignore it. We present the formula for calculating chamber response time. © 2009 Springer Science+Business Media B.V.
Note:
Related Files :
Infrared gas analyser
Laboratory-made chambers
Net CO2 uptake
Open system
Self-clamping chambers
עוד תגיות
תוכן קשור
More details
DOI :
10.1007/s11099-009-0018-3
Article number:
Affiliations:
Database:
סקופוס
Publication Type:
מאמר
;
.
Language:
אנגלית
Editors' remarks:
ID:
21724
Last updated date:
02/03/2022 17:27
Creation date:
16/04/2018 23:46
Scientific Publication
Chamber response time: A neglected issue in gas exchange measurements
47
Weiss, I., Department of Life Sciences, Ben-Gurion University of the Negev, Beer Sheva 84105, Israel
Mizrahi, Y., Department of Life Sciences, Ben-Gurion University of the Negev, Beer Sheva 84105, Israel
Raveh, E., Gilat Research Center, Agricultural Research Organization, Ministry of Agriculture, mobile Post Negev, 85280, Negev, Israel
Chamber response time: A neglected issue in gas exchange measurements
When the dimensions of standard commercial chambers for measuring gas exchange cannot accommodate the object being measured, scientists construct their own chambers. The time needed to reach chamber steady state (chamber response time) depends on net system volume (e.g. chamber and tubing volume) and airflow. Unfortunately, some authors take chamber response time into consideration while others ignore it. We present the formula for calculating chamber response time. © 2009 Springer Science+Business Media B.V.
Scientific Publication
You may also be interested in