Determining the Volume of Sampled Soil When Using the Four‐Electrode Technique
Year:
1980
Authors :
נדלר, אריה
;
.
Volume :
44
Co-Authors:
Facilitators :
From page:
1186
To page:
1190
(
Total pages:
5
)
Abstract:

A theoretical discussion of the ratio between apparent resistivity and real resistivity of a soil layer as a function of (i) layer thickness/electrode spacing ratio; (ii) the soil layer thickness and resistivity of an underlying layer; and (iii) horizontal distance of a different medium from the current electrode is presented. Laboratory experimental work was carried out in order to study the effects the electrode spacing and current density have on the determination of the electrical conductivity of soil solution. It was found out that the depth sensed by a Wenner Configuration would be deeper than the inner electrode spacing for most field situations and especially where there are large variations in conductivity (due to salinity or water content) with depth. The laboratory calibration of the salinity probe should be done in a volume of about 2.5 liters or greater. The volume sensed by this method is greater the lower is the water content. The implications in laboratory calibration‐field measurements relationships are discussed.

Note:
Related Files :
measurement
multi-electrode probe
Resistivity
soil
SOIL ELECTRICAL CONDUCTIVITY
Soil salinity
עוד תגיות
תוכן קשור
More details
DOI :
https://doi.org/10.2136/sssaj1980.03615995004400060010x
Article number:
0
Affiliations:
Database:
Publication Type:
מאמר
;
.
Language:
אנגלית
Editors' remarks:
ID:
50576
Last updated date:
02/03/2022 17:27
Creation date:
29/09/2020 15:36
Scientific Publication
Determining the Volume of Sampled Soil When Using the Four‐Electrode Technique
44
Determining the Volume of Sampled Soil When Using the Four‐Electrode Technique

A theoretical discussion of the ratio between apparent resistivity and real resistivity of a soil layer as a function of (i) layer thickness/electrode spacing ratio; (ii) the soil layer thickness and resistivity of an underlying layer; and (iii) horizontal distance of a different medium from the current electrode is presented. Laboratory experimental work was carried out in order to study the effects the electrode spacing and current density have on the determination of the electrical conductivity of soil solution. It was found out that the depth sensed by a Wenner Configuration would be deeper than the inner electrode spacing for most field situations and especially where there are large variations in conductivity (due to salinity or water content) with depth. The laboratory calibration of the salinity probe should be done in a volume of about 2.5 liters or greater. The volume sensed by this method is greater the lower is the water content. The implications in laboratory calibration‐field measurements relationships are discussed.