נגישות
menu      
Advanced Search
Syntax
Search...
Volcani treasures
About
Terms of use
Manage
Community:
אסיף מאגר המחקר החקלאי
Powered by ClearMash Solutions Ltd -
Application of a multi-layer sampler based on the dialysis cell technique for the study of trace metals in groundwater
Year:
1989
Source of publication :
Applied Geochemistry
Authors :
Amiel Abraham J.
;
.
Volume :
4
Co-Authors:
Magaritz, M., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Wells, M., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Amiel, A.J., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Ronen, D., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Facilitators :
From page:
617
To page:
624
(
Total pages:
8
)
Abstract:
Most studies of metals in groundwater involve sample filtration. A water sampling technique based on dialysis cells has an advantage of in situ separation of particulate (colloidal) matter from the fluid, thus avoiding overload of the membrane during laboratory filtration. A series of laboratory and field experiments were carried out with a multi-layer sampler based on the dialysis cell technique. Results show that (1) the time of equilibration for Cu and Mn is within 2 d, (2) dialysis cells do not absorb these metals, and (3) the metal content measured in the dialysis cells is much lower than that in water taken by bailer and filtered in the laboratory. Measurements of metal profiles in the water table zone of the phreatic Coastal Plain Aquifer of Israel show both vertical and horizontal variations in Mn content which can be related to changes in pH due to biological activity in this aquifer. © 1989.
Note:
Related Files :
dialysis cell
dialysis cell technique
groundwater
groundwater quality
Israel
multi layer sampler
trace metal
water quality analysis
Show More
Related Content
More details
DOI :
10.1016/0883-2927(89)90071-1
Article number:
Affiliations:
Database:
Scopus
Publication Type:
article
;
.
Language:
English
Editors' remarks:
ID:
25619
Last updated date:
02/03/2022 17:27
Creation date:
17/04/2018 00:16
Scientific Publication
Application of a multi-layer sampler based on the dialysis cell technique for the study of trace metals in groundwater
4
Magaritz, M., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Wells, M., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Amiel, A.J., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Ronen, D., Department of Isotope Research, The Weizmann Institute of Science, Rehovot, 76100, Israel
Application of a multi-layer sampler based on the dialysis cell technique for the study of trace metals in groundwater
Most studies of metals in groundwater involve sample filtration. A water sampling technique based on dialysis cells has an advantage of in situ separation of particulate (colloidal) matter from the fluid, thus avoiding overload of the membrane during laboratory filtration. A series of laboratory and field experiments were carried out with a multi-layer sampler based on the dialysis cell technique. Results show that (1) the time of equilibration for Cu and Mn is within 2 d, (2) dialysis cells do not absorb these metals, and (3) the metal content measured in the dialysis cells is much lower than that in water taken by bailer and filtered in the laboratory. Measurements of metal profiles in the water table zone of the phreatic Coastal Plain Aquifer of Israel show both vertical and horizontal variations in Mn content which can be related to changes in pH due to biological activity in this aquifer. © 1989.
Scientific Publication
You may also be interested in