A comparison between experimental and CFD results with regard to flow patterns and ventilation rate of a naturally ventilated greenhouse
Year:
2008
Source of publication :
Acta Horticulturae
Authors :
Liran, Or
;
.
Teitel, Meir
;
.
Volume :
801 PART 2
Co-Authors:
Liran, O., Agricultural Engineering Institute, Agricultural Research Organization, Volcani Center, POB 6, Bet Dagan 50250, Israel
Teitel, M., Agricultural Engineering Institute, Agricultural Research Organization, Volcani Center, POB 6, Bet Dagan 50250, Israel
Ziskind, G., Department of Mechanical Engineering, Ben Gurion University of the Negev, POB 653, Beer Sheva, 84105, Israel
Letan, R., Department of Mechanical Engineering, Ben Gurion University of the Negev, POB 653, Beer Sheva, 84105, Israel
Facilitators :
From page:
917
To page:
924
(
Total pages:
8
)
Abstract:
The paper presents a comparison between CFD and experimental results with regard to flow patterns and ventilation rate of a naturally ventilated small greenhouse. The greenhouse was ventilated by side openings and roses were grown in it. Velocity vectors at several positions inside the greenhouse and near the openings were measured by a 3-D sonic anemometer. Ventilation rate was estimated from the decay rate of a tracer gas concentration and also was calculated from the product of the average air velocity near the openings by the area of the openings. To simulate the airflow within the greenhouse, three cases were investigated using CFD analysis. A very good agreement was obtained between the tracer gas decay method and the calculations using the 3-D anemometer data with regard to the ventilation rate. On the other hand, ventilation rates estimated by the CFD were usually noticeably higher. In some cases, the predicted detailed flow fields differed from the measured velocity vectors. Possible reasons for this disagreement are highlighted and discussed in the paper.
Note:
Related Files :
CFD
Flow patterns
greenhouse
Rosa
Roses
Ventilation
Ventilation,Rosa
Show More
Related Content
More details
DOI :
Article number:
Affiliations:
Database:
Scopus
Publication Type:
Conference paper
;
.
Language:
English
Editors' remarks:
ID:
29457
Last updated date:
02/03/2022 17:27
Creation date:
17/04/2018 00:47
Scientific Publication
A comparison between experimental and CFD results with regard to flow patterns and ventilation rate of a naturally ventilated greenhouse
801 PART 2
Liran, O., Agricultural Engineering Institute, Agricultural Research Organization, Volcani Center, POB 6, Bet Dagan 50250, Israel
Teitel, M., Agricultural Engineering Institute, Agricultural Research Organization, Volcani Center, POB 6, Bet Dagan 50250, Israel
Ziskind, G., Department of Mechanical Engineering, Ben Gurion University of the Negev, POB 653, Beer Sheva, 84105, Israel
Letan, R., Department of Mechanical Engineering, Ben Gurion University of the Negev, POB 653, Beer Sheva, 84105, Israel
A comparison between experimental and CFD results with regard to flow patterns and ventilation rate of a naturally ventilated greenhouse
The paper presents a comparison between CFD and experimental results with regard to flow patterns and ventilation rate of a naturally ventilated small greenhouse. The greenhouse was ventilated by side openings and roses were grown in it. Velocity vectors at several positions inside the greenhouse and near the openings were measured by a 3-D sonic anemometer. Ventilation rate was estimated from the decay rate of a tracer gas concentration and also was calculated from the product of the average air velocity near the openings by the area of the openings. To simulate the airflow within the greenhouse, three cases were investigated using CFD analysis. A very good agreement was obtained between the tracer gas decay method and the calculations using the 3-D anemometer data with regard to the ventilation rate. On the other hand, ventilation rates estimated by the CFD were usually noticeably higher. In some cases, the predicted detailed flow fields differed from the measured velocity vectors. Possible reasons for this disagreement are highlighted and discussed in the paper.